Compare discounted battery and generator backup costs for equal load and service hours across three usage cases.
Battery versus generator inputs
kW
hours
years
%
%
currency
year
currency
per kWh
%
currency/year
currency
litres/hour
per litre
%
currency/year
YOUR RESULTS
Lower expected discounted costGenerator
Expected discounted difference₹44,883.25
Battery discounted cost₹3,68,318.56
Generator discounted cost₹3,23,435.31
Confirm that each option can meet starting surge and continuous power. Battery cycle life, generator part-load fuel use, noise, emissions, fuel delivery, outages and residual value are not monetized. Trust level: engineering estimate; verify site and equipment assumptions before purchase or installation.
View detailed breakdown
Scenario
Battery cost
Generator cost
Difference
Conservative
₹3,63,546.95
₹2,89,484.38
₹74,062.57 generator advantage
Expected
₹3,68,318.56
₹3,23,435.31
₹44,883.25 generator advantage
Optimistic
₹3,73,090.18
₹3,57,386.25
₹15,703.93 generator advantage
HOW THIS RESULT WAS BUILTEngineering estimateEngine energy-decision-1.0.0
Method: compare discounted upfront, energy or fuel, maintenance and entered replacement costs for equal backup hours
Inputs used: Load 2 kW × 200 hours/year for 10 years
Assumptions: Both options serve the same entered load and annual hours Battery round-trip efficiency Generator fuel use at the modelled load
Scope and warnings: Confirm that each option can meet starting surge and continuous power. Battery cycle life, generator part-load fuel use, noise, emissions, fuel delivery, outages and residual value are not monetized.
U.S. Department of Energy · United States government educational resource; technology concepts are broadly applicable · effective As published · reviewed 2026-09-12
high confidence · Engineering estimate
Supports the distinction between power, energy and storage-system limitations.
Exclusions: Not a product-sizing recommendation or outage-resilience guarantee.
UNDERSTAND THE RESULT
How this battery versus generator calculator works
Both paths serve the same entered kW and annual backup hours. Battery cost includes upfront price, charging energy adjusted for round-trip efficiency, maintenance and an optional replacement. Generator cost includes upfront price, fuel use, fuel escalation and maintenance.
A worked example
A 2 kW load used for 200 backup hours needs 400 kWh of delivered energy each year. The battery path buys more charging energy because efficiency is below 100%; the generator path uses entered litres per hour rather than an assumed generic fuel curve.
What does this comparison leave out?
It does not value noise, emissions, fuel delivery, outage duration risk, battery cycle life, residual value or part-load generator efficiency. Confirm both options can supply continuous and starting power before comparing cost.
Calculations run on your device. Review your results before exporting or sharing them.
Match power and service before cost
Enter generator fuel consumption at the load being compared, not only the nameplate full-load value. For batteries, confirm usable energy, continuous inverter power and surge separately; this page models annual delivered energy and cost.
The scenario spread changes backup hours for both options. Battery replacement timing and generator maintenance remain as entered. Test additional cases when outages are irregular or a critical load has a high cost of interruption.